Model PDCR-1730

Water level (pressure) immersion probe with 10 m vented cable for atmospheric
pressure compensation.

Ranges: any range between 0-200 m water column, to be indicated with the order.

Precisión: 0-25 % F.E.

SUBIR

Modelo PDCR-1730

Vented Cable

Additional vented cable for PDCR-1730. Provided by meters

SUBIR

Modelo PULS-62

Model PULS-61

Non-contact, RADAR level sensor (for water and snow).

0-10 or 0-20 meters.

Accuracy:
± 5 mm (for individual mesurements).
± 3 mm (for averaged values, when connected to HYDRODATA-2000/3000C Remote Units).

4-20 mA (two-wire).

Adjustment: By external module (Model PLICSCOM quoted separately), plugged into the sensor, or by PC.

SUBIR

Modelo PULS-62

Model PULS-62

Non-contact, RADAR level sensor (for water and snow).

0-30 meters (programmable).

Accuracy:
± 3 mm ( for individual mesurements).
± 1 mm (for averaged values, when connected to HYDRODATA-2000/3000C Remote Units).


4-20 mA (two-wire).

External module (Model PLICSCOM quoted separately), plugged into the sensor,
or by PC.

SUBIR

Modelo SON-61

Model SON-61/5 (5 meters range)

Non-contact, Ultrasonic continuous water level sensor (compact mount).

Range: 0.25 - 5 meters.

Power: 24 VDC (16...36 VDC).

Output signal: 4-20 mA.

Adjustment: by external module (Model PLICSCOM quoted separately), plugged into the sensor, or by PC.

Accuracy: ± 5 mm.

SUBIR

Modelo SON-61

Model SON-62/8 (8 meters range)

Non-contact, Ultrasonic continuous water level sensor (compact mount)

Range: 0.4 - 8 meters.

Power: 24 VDC (16...36 VDC).

Output signal: 4-20 mA.

Adjustment: by external module (Model PLICSCOM quoted separately), plugged into the sensor, or by PC.

Accuracy: ± 5 mm.

SUBIR

Modelo SON-61

Model SON-63/15 (15 meters range)

Non-contact, Ultrasonic continuous water level sensor (compact mount)

Range: 0.6 - 15 meters.

Power: 24 VDC (16...36 VDC).

Output signal: 4-20 mA.

Adjustment: by external module (Model PLICSCOM quoted separately), plugged into the sensor, or by PC.

Accuracy: ± 5 mm.