Model PDCR-1730
Water level (pressure) immersion probe with 10 m vented cable for atmospheric
pressure compensation.
Ranges: any range between 0-200 m water column, to be indicated with the order.
Precisión: 0-25 % F.E.
Vented Cable
Additional vented cable for PDCR-1730. Provided by meters
Model PULS-61
Non-contact, RADAR level sensor (for water and snow).
0-10 or 0-20 meters.
Accuracy:
± 5 mm (for individual mesurements).
± 3 mm (for averaged values, when connected to HYDRODATA-2000/3000C Remote Units).
4-20 mA (two-wire).
Adjustment: By external module (Model PLICSCOM quoted separately), plugged into the sensor, or by PC.
Model PULS-62
Non-contact, RADAR level sensor (for water and snow).
0-30 meters (programmable).
Accuracy:
± 3 mm ( for individual mesurements).
± 1 mm (for averaged values, when connected to HYDRODATA-2000/3000C Remote Units).
4-20 mA (two-wire).
External module (Model PLICSCOM quoted separately), plugged into the sensor,
or by PC.
Model SON-61/5 (5 meters range)
Non-contact, Ultrasonic continuous water level sensor (compact mount).
Range: 0.25 - 5 meters.
Power: 24 VDC (16...36 VDC).
Output signal: 4-20 mA.
Adjustment: by external module (Model PLICSCOM quoted separately), plugged into the sensor, or by PC.
Accuracy: ± 5 mm.
Model SON-62/8 (8 meters range)
Non-contact, Ultrasonic continuous water level sensor (compact mount)
Range: 0.4 - 8 meters.
Power: 24 VDC (16...36 VDC).
Output signal: 4-20 mA.
Adjustment: by external module (Model PLICSCOM quoted separately), plugged into the sensor, or by PC.
Accuracy: ± 5 mm.
Model SON-63/15 (15 meters range)
Non-contact, Ultrasonic continuous water level sensor (compact mount)
Range: 0.6 - 15 meters.
Power: 24 VDC (16...36 VDC).
Output signal: 4-20 mA.
Adjustment: by external module (Model PLICSCOM quoted separately), plugged into the sensor, or by PC.
Accuracy: ± 5 mm.
Model PLICSCOM
External Module for adjustment of SON-61, SON-62, SON-63 ultrasonic level sensors, and PULS-61/62 RADAR sensors.
© 1974-2008 Geónica, S.A. All Rights Reserved Legal×Privacy Policy