The Mini-Analyser Series offered by GEONICA for water quality continuous on-line mesurements, are ready for direct connection to a single HYDRODATA-2000/3000C Data Acquisition and Transmission Unit or for integration with the Aqualert System, as a part of the continuous water quality surveillance solution offered by GEONICA ( see the Aqualert System description in this website).
These new and small analysers can provide a taylored solution to many specific monitoring needs. Designed specifically to suit certain monitoring situations, such as environmental monitoring , industrial discharge or single point of source monitoring , you are sure to find a configuration of the Mini Analyser that is ready to take on your specific monitoring task.
Designed to be either wall, trailer or bench-top mounted, this compact analyzer, is the solution for continuous unattended analysis and is packed with additional features.
The general specifications of the Mini Analysers are indicated on the bottom of this page.
It is available in three configurations: Physicals, Nutrient and Single Channel variants.
Model Mini-Physicals
This version is configured to perform:
pH, Electrical conductivity, Dissolved oxygen, Turbidity and Temperature.
Oxidation reduction potential - ORP can be added as an additional option.
It is designed to function in an unattended mode whilst deployed in remote locations for environmental applications, connected normally to the HYDRODATA-200/3000C Remote Unit, for Data Acquisition and Data and Alarm Transmission via GPRS, radio, etc.
Model Mini-Nutrients
This version is configured to perform:
Total reactive Phosphorus, Nitrate and Ammonia or Ammonium.
Suitable for monitoring nutrient levels in either environmental applications or wastewater treatment applications, where the analyser can be configured with 4-20mA output for SCADA, or connected normally to the HYDRODATA-200/3000C Remote Unit, for Data Acquisition and Data and Alarm Transmission via GPRS, radio, etc.
Model Single Channel
This version is configured to perform analysis of only one parameter, while offering the complete features and functionality of the complete systems. On board standards and dynamic calibration in association with standard laboratory methodologies ensure that Mini-Analysers provide accurate and laboratory compatible data.
The functionality of the Mini-Analyser allows for unattended operation with a minimum of field visits and the advantage that data review, system monitoring and diagnostics can all be performed via your desktop PC.
Again this single parameter version is connected normally to the HYDRODATA-200/3000C Remote Unit, for Data Acquisition and Data and Alarm Transmission via GPRS, radio, etc.
The compact design of the Mini-Analyser allows for wall mounting or bench top location.
Parameters and Specifications
The functionality of the Mini-Analyser allows for unattended operation with a minimum of field visits and the advantage that data review, system monitoring and diagnostics can all be performed via your desktop PC.
Physicals
pH
EC
DO
ORP
Turbidity
Single Channel and
Nutrients
Nitrate
Phosphate (TRP)
Ammonia
Ammonium
Total Phosphorus
Glass electrode Std Method 4500-H B
Conductivity cell Std. Method 2520-B
Galvanic cell Std. Method 4500-0 G
Platinum electrode Std. Method 2580-B
Nephelometer Std. Method 2130-B
ISE Std. Method 4500-N03 D
Colorimetric Std. Method 4500-P E
Gas Electrode STD. Method 4500-NH3 D
ISE
Colorimetric Std. Method 4500-B
2-12
0-2,000µS/cm
0-20 mg/l
+/-1000mV
0 - 2,000 NTU
0.1-14mg/l
0.1-3ppm
0-14 mg/l
0.3-14 mg/l
3-360 ppb or 0.1-3 ppm
+/- 0.4 pH
+/- 2% FS
+/- 0.2 mg/l
+/- 5% FS
+/- 2.5% FS
+/- 5%
+/- 2%
+/- 5%
+/- 5%
+/- 2%
Physical
Nutrients
Single Channel
Nitrate
Phosphate (TRP)
Ammonia
Ammonium
Total Phosphorus
10 to 30 minutes (dependent on set-up)
50 minutes
15 minutes
12 minutes
20 minutes
15 minutes
30 minutes
Enclosure
Dimensions
Cabinet Weight
Processor
Data Storage
Display
Calibration
Sample Flow Rate
Ambient Conditions
Power Average
Voltage
Alarms
Sampler Output
Output
External Inputs
Scheduling
Communications
Interrogation
Software
IP 54
365x400x430 (WxHxD)
75kgs
80C188
1Mb Total 491K for Data Storage
Optional back lit LCD
User Definable
20-60L/min
5-50'C
15.6VA
85-264 VAC
System and Sample
Optional
4-20 mA or SDI-12 optional
Up to 8 x 4 - 20 mA
25 User Defined Schedules
Landline, GSM or Satellite
RS232